Here is a list of some terms you may encounter when reading through our web site. We have tried to make explanations as easy to understand as possible, but if you are still un-clear please feel free to contact us.
A - B - C - E - F - G - H - I - P - U
A
Aperture - The part of the collector through which light enters. For evacuated tubes this refers to the cross-sectional surface area of the outer clear glass tube measured using the internal diameter, not the outside diameter. (E.g. 0.0548m x 1.72m = 0.094m2). 1.72m is the exposed length of the evacuated tube. Absorber - The part of the collector that actively absorbs the light rays. For solar tubes this is defined as the cross-sectional area of the inner tube (selective coated) measured using the outside diameter. (E.g. 0.047 x 1.72m = 0.08m2) This value is used when calculating efficiency values. For solar tube collectors with reflective panels, the entire circumferential surface area of the inner tube is often used when calculating absorber area, as the reflective panel is supposed to reflect light onto underside of the evacuated tube.
B
BTU - Stands for British Thermal Units. This is an imperial unit of measurement for heat widely used in the US and also in the UK. The conversion to the metric unit kWh is: 1 kWh = 3412Btu, and for surface area values, 1kWh/m2/day = 314Btu/ft2/day
C
Collector - A solar collector is not really a solar water heater. A solar water heater is a system which may include a tank, pump, controller and solar collector panel, etc. A solar collector is that part of the system which absorbs the sun's energy and converts it into heat. We have different kind of collector like Non-pressure System Collector, Heat Pipe Collector and U-pipe Collector. Celsius - The metric unit for temperature measurement. Convert as follows: Fahrenheit = (oC x 1.8) + 32 Celsius = (oF - 32)/1.8
E
Efficiency - Solar collector efficiency is usually expressed as a percentage value, or in a performance graph. When assessing a collector's performance make sure it is based on the correct surface area values. E.g. If performance values are based on gross area, then the gross area must be used when determining total heat output. IAM values have a significant influence on actual heat output throughout the day, and should be considered. Looking at just the percentage efficiency value will not give a true indication of daily heat output. Efficiency testing is usually completed by testing bodies such as DIN CERTCO, SPF, SRCC, other government approved testing bodies. Tm* is the x axis value on performance graphs for solar collectors. Tm* is calculated as: (water temp - ambient temp)/Insolation E.g. (44oC - 20oC)/800Watts = 0.03
F
Flow Rate - The volume of water flowing through plumbing in a given period of time. Usually it is measured in volume/minute or volume/hour. 1 Litre/min = 0.264 US Gallon/min
G
Gross Area - The total surface area of the collector including the frame, manifold and absorber. This area is often used when comparing collectors, but a better comparison to use is value for money. Roof size is not usually a limiting factor for domestic solar water heating installations, so the size of the collector is not really that important.
H
Heat Pipe - An evacuated rod or pipe used for heat transfer. Click here for more information.
I
Irradiation, Irradiance, Insolation - Basically they are the same. Don't confuse insolation with insulation - the one letter change makes a big difference. Insolation refers to the amount of sunlight falling on the earth. Click here for more information. Insulation - The ability to protect against transfer of heat/cold. AUDSUN solar collectors use compressed glass wool and polyurethane foam to insulate the header from heat loss. Glass wool has excellent insulation properties, is very light and can withstand high temperatures, making it an ideal choice for a solar collector. It is made from a least 80% old glass bottles and can be recycled so is very environmentally friendly.
P
Pressure - Refers to the water pressure in the system. The conversions for the most commonly used units are: 1 bar = 1.02kg/cm2 = 14.5psi = 100kPa = 0.1MPa = 10m water head
U
U-pipe - "U" shape pipe inside every evacuated tube for heat transfer. Click here for more information. If there are any words that you think we should add to this glossary, please let us know. |