Component Specifications |
Copper Header |
Material |
≥ 99.93% Copper |
Inlet/Outlet |
1/2" |
Recommended Flow Rate |
3L/min |
Max. Working Pressure |
0.6MPa |
Testing Pressure |
1.2MPa |
Manifold Casing |
Material |
Aluminum Alloy |
Tube Central Distance |
80mm |
Insulation |
Insulation Material |
Glass Wool and Polyurethane Foam |
Insulation Factor |
K=0.019W/mk |
Frame |
Material |
Aluminium Alloy with Stainless Steel Adjustable Baseboards for Sloping Roof |
Reflectors |
Diffuse Flat Aluminium Ginning Panel with Aluminium Alloy Borders |
Flat Roof Brackets (optional) |
Aluminum Alloy, Installation Angel:40 |
Adjustable Brackets (optional) |
Aluminum Alloy, Installation angle available: 28, 31, 35, 39, 43, 47, 52,57 |
Evacuated Tubes |
Size |
Φ58x1800mm |
Tube Thickness |
1.6mm |
Weight: |
2.5kgs |
Solar Tube Material |
High Borosilicate Glass 3.3 |
Selective Coating |
Al-N/Al |
Absorptance |
≥92% |
Emittance(80℃) |
<0.8 |
Vacuum |
≤5x10-3Pa |
Stagnation Temperature |
>230℃ |
Heat Loss |
<0.8W/(m2)℃ |
Testing Pressure |
0.6MPa |
Heat Pipe & Heat Transfer Fins |
Material: |
Copper |
Heat Transfer Liquid |
Propylene Glycol or Water |
Maximum Working Temperature |
300℃ |
Startup Temperature |
<25℃ |
Heat Transfer Fins |
Aluminum Sheet |
Rubber Components |
Tube Support (black) |
High Temp. Nylon |
Wind-resistance Gasket(gray) |
Silicone Rubber |
Tube Sleeve Gasket(white) |
Silicone Rubber |