| Optional Accessories |
|
|
F8 Series Intelligent Controller
Wattage:1.5-2.0kW
Functions:
1.Water temperature and level display
2.Manual heating or auto heating by electricity
3.Manual water inlet or auto water inlet by electromagnetic valve
4.Water level setting
5.Electric heating and keep warm
6.Memory when power off
7.Safety protection
8.Malfunction alarm
|
|
|
|
|
Backup Heating Element
Wattage: 1.5-2.0kW
Functions:
1.Manual heating by electricity
2.Electric heating and keep warm
3.Electric leakage protection
|
|
|
|
|
Steam Vent Valve
1. A safety valve for the pressurized storage cylinder or split pressure system solar collectors to avoid the piping becoming air bound, purging un-wanted air in the water circulation loop.
2. Release Pressure: at 120℃ or at 1.0MPa.
|
|
|
|
|
Air Vent Valve
A safty valve designed for Non-pressure System water tank to keep it open to the air.
|
|
|
|
|
T.P. Valve
1. A safety valve for over temperature and over pressure in the storage cyliner.
2. Release Pressure: at 99℃/210℉ or at 0.7MPa.
|
|
|
|
|
Pressure Relief Valve
1. A unidirectional safety valve installed at the water inlet of a pressurized storage cylinder.
2. Release Pressure: at 0.7MPa.
|
|
|
|
|
Hot Water Booster Pump
1.High temperature resistance
2.Using cooling fan,it can be used for 100℃ hot water
3.Low noise
4.With interior special rustproof treatment
5.The most economized on energy
6.Light and durable design
7.Closed style motor with long life
Model |
Power Supply |
Rated Wattage(w) |
Rated Lift(m) |
Max. Flow(t/h) |
Tube Diameter (mm) |
Weigh(kg) |
PB-H089EA |
220V/50Hz |
60 |
9 |
2.1 |
15 |
4 |
PB-H169EA |
220V/50Hz |
160 |
15 |
2.7 |
15 |
7 |
|
|
|
|
|
|
Circulation Pump
A circulation pump is normally controlled by the solar controller to move water between the solar collectors and the hot water storage cylinder.
Model |
Power Supply |
Rated Wattage(w) |
Rated Lift(m) |
Max. Flow (t/h) |
Tube Diameter (mm) |
Weigh(kg) |
PH-041E |
220V/50Hz |
40 |
3.5 |
3.6 |
25 |
5 |
PH-101E |
220V/50Hz |
100 |
5 |
7.8 |
40 |
11 |
PH-123E |
220V/50Hz |
125 |
5 |
11.4 |
50 |
15 |
PH-251E |
220V/50Hz |
250 |
7.5 |
13.8 |
65 |
20 |
PH-400E |
220V/50Hz |
400 |
15.5 |
19.8 |
80 |
30 |
PH-401E |
220V/50Hz |
400 |
19.5 |
17.4 |
50 |
30 |
|
|
|
|
|
|
Temperature Controller
Model:SA135N
|
|
|
|
|
Temperature Difference Controller
Model:SA136N
Feature:
1. For controlling the circulation of the solar collectors.
2. Digital display for temperature difference.
3. Adjustable temperature difference.
|
|
|
|
|
Insulation Tube
Hot water pipeline should be insulated in order to avoid heat loss of hot water while flowing.
|
|
|
|
|
Gravity Feed Tank
Feature:
1. For auto water inlet.
2.Installed on the back of the storage cylinder to maintain the same water level with the storage cylinder.
3. Made of stainless steel SUS304.
|
|
|
|
|
Insulation Feed Tank
Feature:
1. For auto water inlet.
2. With Insulation for Installation on top of the storage cylinder.
|
|
|
|
|
Expansion Tank
An expansion tank is a safety device to release the pressure in the circulation between the solar collectors and the heat exchanger of storage cylinder.
|
|
|
|
|
Heat Pipe
The heat pipe transmits heat to its tip which is plugged into the collector's heat transfer manifold.
|
|
|
|
|
Evacuated Tube
1. Configuration:Two concentric boron silicon glass tube.
2.Coating and Technology:Gladed AL/N/AL selective surface by sputtering.
3. Solar Absorptance: 0.88-0.94.
4.Emittance (80℃): 0.08-0.04
5.Vacuum Jacket Pressure: ≤5x10-3Pa
6.Stagnation Temp.: over 230℃
7.Impact Resistance: withstand hailstone of 25mm in diameter
8.Strenth (Tested Pressure): 0.6MPa
|
|
|
|
|
Rubber Components
For Non pressure system:
1.Tube Support (green)
2.Wind-resistance Gasket(green)
3.Seal Gasket(white)
|
|
|
|
|
Rubber Components
For Pressure System:
1.Tube Support (black)
2.Wind-resistance Gasket(green)
3.Tube Sleeve Gasket(white)
|
|
|
|
|
Temperature Sensor
|